Boiler type Enduro TI ETI-1000

Error code F05

Cause:

F05 indicates the boiler supply temperature

is excessive. When accompanied by the

red FAULT light and LOCKOUT flashing on

the display, this code indicates the supply

sensor temperature has exceeded 230oF and

a serious safety issue exists. The boiler will

not restart until a technician determines and

repairs the cause of excessive temperature

and pushes RESET on the display.

If the FAULT light is not illuminated and

this message is displayed, the supply

temperature of the boiler is at or above

210oF. The message will clear automatically

when the temperature drops below 194oF.

During the time that this fault is displayed,

the pump will be on.

Solution:

- Check circulator pump operation.

- Ensure adequate flow through the boiler by accessing the status menu and determining there is less than a 50°F rise from the return thermistor to the supply thermistor.

- Check the direction of flow off the boiler circulator.

- Troubleshoot the dual supply thermistor by following steps in F02.