nl en de
Selecteer uw gewenste taal

In welk land bevindt uw cv ketel zich?

Storingen


Ketel type MPO-IQ147

Storingscode ErP25

Oorzaak:

Manual Reset Required

 

Oplossing:

Check Oil Primary and Option Panel Displays:
-If Option Panel display shows “OL- “, Open Limit: the display will indicate the card that has a manual reset lockout.  Follow instructions included with card to reset the lockout.
-If The Oil Primary is locked out refer to ERP 20 for additional information.